OPERATING INSTRUCTIONS AND SPECIFICATIONS
NI 9401
8-Channel, TTL Digital Input/Output Module
ni.com/manuals
DeutschFrançais
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - DeutschFrançais

OPERATING INSTRUCTIONS AND SPECIFICATIONSNI 94018-Channel, TTL Digital Input/Output Moduleni.com/manualsDeutschFrançais

Seite 2

NI 9401 Operating Instructions and Specifications 10 ni.comOvercurrent ProtectionOvercurrent protection on the NI 9401 allows only a specified amount

Seite 3 - Safety Guidelines

© National Instruments Corp. 11 NI 9401 Operating Instructions and SpecificationsSleep ModeThis module supports a low-power sleep mode. Support for sl

Seite 4

NI 9401 Operating Instructions and Specifications 12 ni.comSpecificationsThe following specifications are typical for the range –40 to 70 °C unless ot

Seite 5

© National Instruments Corp. 13 NI 9401 Operating Instructions and SpecificationsDigital logic levelsInputVoltage ... 5.

Seite 6 - Connecting the NI 9401

NI 9401 Operating Instructions and Specifications 14 ni.comMaximum input signal switching frequency by number of input channels, per channel8 input ch

Seite 7

© National Instruments Corp. 15 NI 9401 Operating Instructions and SpecificationsMTBF ... 1,244,763 hours

Seite 8

NI 9401 Operating Instructions and Specifications 16 ni.comSafetyMaximum Voltage1Connect only voltages that are within the following limits.Channel-to

Seite 9

© National Instruments Corp. 17 NI 9401 Operating Instructions and Specificationssupply system that powers equipment. This category is for measurement

Seite 10 - Overcurrent Protection

NI 9401 Operating Instructions and Specifications 18 ni.comHazardous LocationsU.S. (UL) ... Class I, Division 2

Seite 11 - Sleep Mode

© National Instruments Corp. 19 NI 9401 Operating Instructions and SpecificationsOperating humidity(IEC 60068-2-56)... 10 t

Seite 12 - Specifications

NI 9401 Operating Instructions and Specifications 2 ni.comThis document describes how to use the National Instruments 9401 and includes specifications

Seite 13

NI 9401 Operating Instructions and Specifications 20 ni.comElectromagnetic CompatibilityThis product is designed to meet the requirements of the follo

Seite 14

© National Instruments Corp. 21 NI 9401 Operating Instructions and Specificationsni.com/certification, search by module number or product line, and cl

Seite 15 - Physical Characteristics

NI 9401 Operating Instructions and Specifications 22 ni.comWhere to Go for SupportThe National Instruments Web site is your complete resource for tech

Seite 16 - Isolation Voltages

© National Instruments Corp. 23 NI 9401 Operating Instructions and Specificationstelephone support outside the United States, contact your local branc

Seite 17 - Safety Standards

© 2005–2008 National Instruments Corp. All rights reserved.374068D-01 Jun08National Instruments, NI, ni.com, and LabVIEW are trademarks of National In

Seite 18 - Environmental

© National Instruments Corp. 3 NI 9401 Operating Instructions and SpecificationsSafety GuidelinesOperate the NI 9401 only as described in these operat

Seite 19 - Shock and Vibration

NI 9401 Operating Instructions and Specifications 4 ni.comCaution Substitution of components may impair suitability for Class I, Division 2.Caution Fo

Seite 20 - CE Compliance

© National Instruments Corp. 5 NI 9401 Operating Instructions and SpecificationsSpecial Conditions for Marine ApplicationsSome modules are Lloyd’s Reg

Seite 21 - Environmental Management

NI 9401 Operating Instructions and Specifications 6 ni.comConnecting the NI 9401The NI 9401 has a 25-pin DSUB connector that provides connections for

Seite 22 - Where to Go for Support

© National Instruments Corp. 7 NI 9401 Operating Instructions and SpecificationsEach channel has a DIO pin to which you can connect a digital input or

Seite 23

NI 9401 Operating Instructions and Specifications 8 ni.comFigure 2 illustrates how to connect an SPI device to the NI 9401. In this example, the three

Seite 24 - -01 Jun08

© National Instruments Corp. 9 NI 9401 Operating Instructions and SpecificationsFigure 3 illustrates how to connect several types of digital devices t